1.
Braz. j. pharm. sci ; 51(2): 285-294, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755069

ABSTRACT

This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.87, and accuracy (relative error) was better than 4.12%. The method developed in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. In addition, the proposed technique was successfully applied to spiked human serum samples. No electro-active interferences from the endogenous substances were found in human serum...


Este artigo descreve um método de voltametria de pulso diferencial (VPD) para a determinação de diclofenaco em preparações farmacêuticas e em soro humano. O método proposto foi baseado em eletroxidação de diclofenaco no eléctrodo de platina em solução 0,1 M TBAClO4/acetonitrila. Dois picos de oxidação bem definidos foram observados em 0,87 e 1,27 V, respectivamente. As curvas de calibração obtidas utilizando-se valores de corrente medidos por segundo pico foram lineares no intervalo de concentração de 1,5-17,5 μg mL-1e 2-20 μg mL-1em eletrólito suporte e soro, respectivamente. Precisão e exatidão também foram verificadas em todos os meios. Valores de precisão intra- e inter-dia para o diclofenaco foram inferiores a 3.87 e a precisão (erro relativo) foi melhor do que 4,12%. O método desenvolvido neste estudo é exato, preciso e pode ser facilmente aplicado a Diclomec, Dicloflam e comprimidos Voltaren, como preparação farmacêutica. Além disso, a técnica proposta foi aplicada com sucesso em amostras de soro humano. Não se observaram interferências das substâncias endógenas no soro humano...


Subject(s)
Humans , Diclofenac/analysis , Diclofenac/pharmacology , Diclofenac/blood , Clinical Chemistry Tests/methods , Chemistry, Pharmaceutical/methods , Electrochemical Techniques/methods
2.
Braz. j. pharm. sci ; 51(1): 43-52, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-751362

ABSTRACT

One titrimetric and two spectrophotometric methods are proposed for the determination of diethylcarbamazine citrate (DEC) in bulk drug and in formulations using potassium iodate and potassium iodide as reagent. The methods employ the well-known analytical reaction between iodate and iodide in the presence of acid. In titrimetry (method A), the drug was treated with a measured excess of thiosulfate in the presence of unmeasured excess of iodate-iodide mixture and after a standing time of 10 min, the surplus thiosulfate was determined by back titration with iodine towards starch end point. Titrimetric assay is based on a 1:3 reaction stoichiometry between DEC and iodine and the method is applicable over 2.0-10.0 mg range. The liberated iodine is measured spectrophotometrically at 370 nm (method B) or the iodine-starch complex measured at 570 nm (method C). In both methods, the absorbance is found to be linearly dependent on the concentration of iodine, which in turn is related to DEC concentration. The calibration curves are linear over 2.5-50 and 2.5-30 µg mL-1 DEC for method B and method C, respectively. The calculated molar absorptivity and Sandell sensitivity values were 6.48×103 L mol-1 cm-1 and 0.0604 µg cm-2, respectively, for method B, and their respective values for method C are 9.96×103 L mol-1 cm-1 and 0.0393 µg cm-2. The intra-day and inter-day accuracy and precision studies were carried out according to the ICH guidelines. The methods were successfully applied to the analysis of DEC formulations.


Propõem-se titulação e dois métodos espectrofotométricos para a determinação de citrato de dietilcarbamazina (DEC) a granel e em suas formulações, usando iodato de potássio e iodeto de potássio como reagente. Os métodos utilizam a reação analítica conhecida entre iodato e iodeto, na presença de ácido. Na titulometria (Método A), o fármaco foi tratado com excesso medido de tiossulfato, na presença de excesso não medido de mistura iodato-iodeto e, depois de um tempo de repouso de 10 min, o excesso de tiossulfato foi determinado por titulação de retorno com iodo até o ponto final com amido. A titulação é baseada em reação com estequiometria 1:3 entre DEC e iodo e o método é aplicável na faixa de 2.0-10.0 mg. O iodo liberado é medido espectrofotometricamente a 370 nm (método B) ou o complexo de iodo-amido medido a 570 nm (método C). Em ambos os métodos, a absorvância é considerada linearmente dependente da concentração de iodo, a qual, por sua vez, está relacionada à concentração de DEC. As curvas de calibração são lineares para concentrações de DEC de 2.5-50 e 2.5-30 mg mL- 1 para o método B e para o método C, respectivamente. A absortividade molar calculada e os valores de sensibilidade Sandel foram 6.48×103 L mol-1 cm- 1 e 0.0604 ug cm-2, respectivamente, para o método B, e os seus respectivos valores para o método C são 9.96×103 L mol-1 cm-1 e 0.0393 mg cm-2. Os estudos de exatidão e precisão intra-dia e inter-dia foram realizados de acordo com as diretrizes da ICH. Os métodos foram aplicados com sucesso na análise de formulações de DEC.


Subject(s)
Spectrophotometry , Diethylcarbamazine/analysis , Iodates/analysis , Iodides/analysis , Chemistry, Pharmaceutical/classification , Titrimetry/methods